13 A Plugs, Socket-outlets and Adaptors: Specification for - download pdf or read online

By BS

ISBN-10: 0580223051

ISBN-13: 9780580223051

BS 1363-1:2016 specifies standards for thirteen A fused plugs having insulating sleeves online and impartial pins, for family, advertisement and lightweight business reasons, with specific connection with protection in general use. The plugs are compatible for the relationship of transportable home equipment, sound-vision gear, luminaires, and so forth. in a.c. circuits basically, working at voltages no longer exceeding 250 V r.m.s. at 50 Hz. extra requisites are incorporated for plugs compatible for electrical car charging. standards are particular for plugs incorporating a fuse hyperlink conforming to BS 1362:1973. The plugs will be rewirable or non-rewirable entire with versatile cable. different types of plugs are unique protecting common and tough use. Rewirable plugs are meant to be used with versatile cables conforming to the correct elements of BS EN 50525 (see Annex H), having conductor cross-sectional components from half mm2 to 1.5 mm2 inclusive.

Show description

Read Online or Download 13 A Plugs, Socket-outlets and Adaptors: Specification for Rewirable and Non-rewirable 13 A Fused Plugs BS 1363 PDF

Similar nonfiction_2 books

Download e-book for kindle: Handbook of Advanced Electronic and Photonic Materials and by Hari Singh Nalwa

Digital and photonic fabrics mentioned during this guide are the most important components of persisted medical and technological advances within the twenty first century. The digital and photonic fabrics comprising this guide contain semiconductors, superconductors, ferroelectrics, liquid crystals, undertaking polymers, natural and superconductors, conductors, nonlinear optical and optoelectronic fabrics, electrochromic fabrics, laser fabrics, photoconductors, photovoltaic and electroluminescent fabrics, dielectric fabrics, nanostructured fabrics, supramolecular and self-asemblies, silicon and glasses, photosynthetic and respiration proteins, and so forth, and so forth.

Download PDF by Ivan Cury: Directing and Producing for Television, Third Edition: A

Directing and generating for tv offers you the instruments you will have to direct and bring successfully in a number of settings. in accordance with his years of expertise within the and instructing the topic, Cury illustrates basic rules with attractive anecdotes that train via instance. perfect for college students in tv creation classes in addition to pros, Directing and generating for tv addresses severe creation options for varied codecs together with panel courses, demonstration, scripted, tune, advertisements, PSAs, information, documentaries, distant broadcasting, and activities.

Harold Bloom's Alan Patton's Cry, the Beloved Country (Bloom's Guides) PDF

Alan Patton's Cry, The loved nation, a part of Chelsea apartment Publishers' Bloom's courses assortment, offers concise serious excerpts from Cry, The loved nation to supply a scholarly evaluate of the paintings. This complete examine consultant additionally positive factors "The tale at the back of the tale" which info the stipulations lower than which Cry, The loved state was once written.

Additional resources for 13 A Plugs, Socket-outlets and Adaptors: Specification for Rewirable and Non-rewirable 13 A Fused Plugs BS 1363

Sample text

Metal shall then be filed carefully from the resistive element over as long a length as is possible and the assembly rechecked until the desired watts loss is achieved. One end cap shall then be unsoldered, a standard ceramic body fitted, the cavity filled and the end cap resoldered in position making sure the shoulder of the element is butted to the inside face of the end cap; the ceramic body shall not interfere with this condition. 2 and adjusted if necessary. The resulting calibrated link shall be marked “NOT A FUSE” on the ceramic body and shall dimensionally be in accordance with BS 1362:1973.

4 wall thickness “t” [see Figure 28b)]. The resistive element shoulders shall be firmly butted to the inside faces of the end caps and soldered using a tin silver solder, grade 96S, as specified in BS 219:1977. 2. Metal shall then be filed carefully from the resistive element over as long a length as is possible and the assembly rechecked until the desired watts loss is achieved. One end cap shall then be unsoldered, a standard ceramic body fitted, the cavity filled and the end cap resoldered in position making sure the shoulder of the element is butted to the inside face of the end cap; the ceramic body shall not interfere with this condition.

The plug is fixed to the oscillating member of the apparatus so that when this is vertical the axis of the flexible cord at the point of entry is vertical and passes through the axis of oscillation. Samples with flat flexible cords are mounted so that the major axis of the section is parallel to the axis of oscillation. The flexible cord is loaded with a weight as given in Table 2. The distance between the point of entry to the plug and the axis of oscillation is adjusted so that the weight makes the minimum lateral movement as the oscillating member moves.

Download PDF sample

13 A Plugs, Socket-outlets and Adaptors: Specification for Rewirable and Non-rewirable 13 A Fused Plugs BS 1363 by BS


by Charles
4.5

Rated 4.21 of 5 – based on 25 votes